Thermal Conduction

Quokka solves explicit, flux-limited thermal conduction as a Strang-split source term on the gas internal energy. The conductivity model (constant or Spitzer) and the geometry (isotropic or field-aligned) are selected at compile time in the problem’s Physics_Traits. Conduction is then switched on at runtime with conduction.enabled = 1.

Choosing a model and geometry

template <> struct Physics_Traits<MyProblem> : DefaultPhysicsTraits {
    static constexpr bool is_hydro_enabled = true;
    static constexpr ConductionModel conduction_model = ConductionModel::spitzer;
    static constexpr ConductionGeometry conduction_geometry = ConductionGeometry::isotropic;
};
conduction_modelConductivity \(\kappa\)Set by
none (default)no conduction—
constant\(\kappa = \kappa_0\)conduction.* prefactors in the input file
spitzer\(\kappa = \kappa_0 T^{5/2}\)conduction.* prefactors in the input file
problem_defined\(\kappa(\rho, T)\)computeConductivity in the problem file
conduction_geometryHeat fluxSolver
isotropic (default)\(\mathbf{q} = -\kappa \nabla T\)IsoConduction
anisotropicsee belowAnisoConduction (Sharma & Hammett 2007); requires is_mhd_enabled = true

In the anisotropic geometry, heat flows along the unit magnetic-field vector \(\hat{\mathbf{b}} = \mathbf{B}/|\mathbf{B}|\) with conductivity \(\kappa_\parallel\), and across it with \(\kappa_\perp\):

Setting \(\kappa_\perp = \kappa_\parallel\) recovers the isotropic flux. In both geometries, each face-normal component \(q\) of the classical flux is then saturated (Cowie & McKee 1977):

where \(f_{\rm sat}\) is conduction.saturation_factor, \(\phi\) is conduction.flux_limiter_phi, and \(c_s\) is the sound speed.

Units

Conductivities are always given as a full conductivity \(\kappa\), in erg cm\(^{-1}\) s\(^{-1}\) K\(^{-1}\), in both geometries. For spitzer, the prefactor \(\kappa_0\) is in erg cm\(^{-1}\) s\(^{-1}\) K\(^{-7/2}\). With a non-CGS unit_system, use the corresponding code units.

Internally, both solvers obtain \(\kappa\) through quokka::conduction::EvaluateConductivity (src/conduction/conductivity.hpp). In the notation of Sharma & Hammett (2007), whose flux is \(\mathbf{q} = -n k_B \chi \nabla T\), \(\kappa = n k_B \chi\); the solvers only ever need this product, so the diffusivity \(\chi\) is never formed.

Problem-defined conductivity

With ConductionModel::problem_defined, specialize computeConductivity in the problem file. It returns \(\{\kappa_\parallel, \kappa_\perp\}\); in the isotropic geometry only the first component is used. This path is currently tested by ThermalConductionSpitzerGaussian.

template <>
AMREX_GPU_HOST_DEVICE AMREX_FORCE_INLINE auto computeConductivity<MyProblem>(amrex::Real rho, amrex::Real Tgas)
    -> quokka::valarray<amrex::Real, 2>
{
    return {kappa0 * std::pow(Tgas, 2.5), 0.0};
}

The function runs on the GPU, so it must not use host-only data; use constexpr constants for any parameters. Both returned conductivities must be non-negative, and in the anisotropic geometry \(\kappa_\perp \le \kappa_\parallel\), because the anisotropic solver’s L2 limiter relies on \((\kappa_\parallel - \kappa_\perp) \hat{b}_n^2 \ge 0\) (checked by an assertion in debug builds). If a problem selects problem_defined without specializing computeConductivity, it fails to compile.

The solvers evaluate \(\kappa\) at face centres (isotropic, from the face-averaged \(\rho\) and \(T\)) or at cell corners (anisotropic, from the average of the adjacent cells).

Input parameters

The constant and spitzer models read their prefactor from the key that matches the geometry:

GeometryKeys
isotropicconduction.conductivity_prefactor (required when conduction is enabled)
anisotropicconduction.kappaPar (required when conduction is enabled), conduction.kappaPerp (optional, default 0)

With the anisotropic geometry, conduction.aniso_flux_limiter selects the limiter for the transverse (cross) terms of the flux, mc (default) or minmod, for any conduction_model.

With conduction.enabled = 1, Quokka aborts at startup in these cases:

  • a prefactor is set that does not match the geometry, or any prefactor is set with problem_defined;
  • conduction.aniso_flux_limiter is set with the isotropic geometry, or is not mc or minmod;
  • a prefactor is negative, or conduction.kappaPerp is larger than conduction.kappaPar;
  • the problem’s conduction_model is none.

With conduction.enabled = 0, the prefactor and limiter keys are ignored. Quokka always aborts if conduction.enabled is not 0 or 1, or if the input file still sets the removed conduction.conduction_type key.

See Runtime parameters for the full list of conduction.* parameters.

Timestep

The explicit conduction timestep is the minimum over all cells of

where \(C\) is conduction.conduction_cfl, \(e\) is the internal energy per unit volume, and \(D\) is evaluated with each cell’s own \(\rho\) and \(T\).

Test problems

ProblemModelGeometry
ThermalConductionConstantAMRconstantisotropic
ThermalConductionPattlespitzerisotropic
ThermalConductionSpitzerGaussianproblem_defined (Spitzer)isotropic
ThermalConductionAnisoconstantanisotropic
ThermalConductionAnisoGaussianconstant (with \(\kappa_\perp > 0\))anisotropic
ThermalConductionAnisoPattlespitzeranisotropic

The anisotropic test problems are built only when AMReX_SPACEDIM = 3.